Skip to main content

Transformer Construction

Transformer Construction

The three main parts of a transformer:

  • Primary Winding of Transformer
  • Magnetic Core of Transformer
  • Secondary Winding of Transformer

Primary Winding of Transformer

Which produces magnetic flux when it is connected to an electrical source.

Magnetic Core of Transformer

The magnetic flux produced by the primary winding, that will pass through this low reluctance path linked with secondary winding and create a closed magnetic circuit.

Secondary Winding of Transformer

The flux, produced by primary winding, passes through the core, will link with the secondary winding. This winding also wounds on the same core and gives the desired output of the transformer.


Comments

Popular posts from this blog

Auto Transformer: What is it? (Definition, Theory & Diagram)

  W hat is an Autotransformer? An autotransformer (or auto transformer ) is a type of electrical transformer with only one winding. The “auto” prefix refers to the single coil acting alone (Greek for “self”) – not to any automatic mechanism. An auto transformer is similar to a two winding transformer but varies in the way the primary and secondary winding of the transformer are interrelated. Autotransformer Theory In an auto transformer, one single winding is used as primary winding as well as secondary winding. But in two windings transformer two different windings are used for primary and secondary purpose. A circuit diagram of auto transformer is shown below. The winding AB of total turns N 1 is considered as primary winding. This winding is tapped from point ′C′ and the portion BC is considered as secondary. Let’s assume the number of turns in between points ′B′ and ′C′ is N 2 . If V 1 voltage is applied across the winding i.e. in between ′A′ and ′C′. Hence, the voltage ...

Hysteresis Eddy Current Iron or Core Losses and Copper Loss in Transformer

Losses in Transformer As the electrical transformer is a static device, mechanical loss in transformer normally does not come into picture. We generally consider only electrical losses in transformer . Loss in any machine is broadly defined as difference between input power and output power. When input power is supplied to the primary of transformer , some portion of that power is used to compensate core losses in transformer i.e. Hysteresis loss in transformer and Eddy current loss in transformer core and some portion of the input power is lost as I 2 R loss and dissipated as heat in the primary and secondary windings, because these windings have some internal resistance in them. The first one is called core loss or iron loss in transformer and the later is known as ohmic loss or copper loss in transformer . Another loss occurs in transformer, known as Stray Loss, due to Stray fluxes link with the mechanical structure and winding conductors. Copper Loss in Transformer Copper loss...

Shell Type Transformer: What is it? And it's Applications

D epending on the construction of its magnetic core, we can categorize transformers into two types: Shell Type Transformer Core Type Transformer Core of Shell Type Transformer We use ‘E’s and ‘L’s shape laminations to make the core of the shell-type transformer . Limb of Shell Type Transformer The core of a single phase shell type transformer is constructed with of three limbs (legs). This design increases the mechanical strength of the core. It also improves the protection of windings from external mechanical shocks. The HV and LV windings are wound around the central limb. The central limb carries the entire flux (φ), whereas the side limbs carry half of the flux (φ/2). Hence, to accommodate the flux the cross-section of the central limb is twice than that of the side limbs. The magnetic flux flows through two closed magnetic paths which decrease the core losses and hence increase the efficiency of transformer . So, shell type transformer gives more output compared to similar c...